Book a Demo

Achieve RESET Air Certification with Kaiterra IAQ Monitoring

Our RESET-Certified Grade B air quality monitors are designed to help you achieve RESET Air Certification.

Building Certification - RESET

By implementing continuous air quality monitoring solutions by Kaiterra, you can achieve RESET Air Certification

Commercial Interior
PM2.5
Measure and meet performance target for particulate matter
Kaiterra monitors measure PM2.5 and help you meet this requirement.

Acceptable: < 35 μg/m³
High Performance: < 12 μg/m³
arrow-up
TVOC
Measure and meet performance target for total volatile organic compounds
Kaiterra monitors measure TVOC and help you meet this requirement.

Acceptable: < 500 ug/m³
High Performance: < 400 ug/m³
arrow-up
CO2
Measure and meet performance target for carbon dioxide
Kaiterra monitors measure CO2 and help you meet this requirement.

Acceptable: < 1000 ppm
High Performance: < 600 ppm
arrow-up
Temp
Measure and monitor temperature
Kaiterra monitors measure dry bulb temperature and help you meet this requirement.
arrow-up
RH
Measure and monitor relative humidity
Kaiterra monitors measure relative humidity and help you meet this requirement.
arrow-up


Core & Shell
PM2.5
Measure and meet performance target for particulate matter
Kaiterra monitors measure PM2.5 and help you meet this requirement.

Target threshold: < 12 μg/m³
arrow-up
TVOC
Measure and meet performance target for total volatile organic compounds
Kaiterra monitors measure TVOC and help you meet this requirement.

Target threshold: < 400 ug/m³
arrow-up
CO2
Measure and meet performance target for carbon dioxide
Kaiterra monitors measure CO2 and help you meet this requirement.

Target threshold: < 800 ppm
arrow-up
Temp
Measure and monitor temperature
Kaiterra monitors measure dry bulb temperature and help you meet this requirement.
arrow-up
RH
Measure and monitor relative humidity
Kaiterra monitors measure relative humidity and help you meet this requirement.
arrow-up

Frequently asked questions

Are Kaiterra monitors RESET-Certified?
Kaiterra’s air quality monitors are RESET-Certified Grade B devices, and meet all the hardware requirements for RESET Certification.
How often are sensor modules replaced, and are certificates of calibration provided?
RESET typically requires annual sensor recalibration, which means that you will need to change your sensor modules every 12 months to meet the requirements. With an innovative modular design, Kaiterra IAQ monitors can be easily recalibrated by swapping out old sensors for new ones. New sensors come with a certificate of calibration.
 
How many monitors do I need for RESET Certification?

RESET outlines a set of criteria for monitor installation to ensure ongoing and accurate monitoring and communication:

  • Deploy one monitor for each regularly occupied space type (any space type that is occupied for at least one hour per day).
  • Install at least one monitor per 5382 ft² (500 m²).
Where should I place monitors?

Monitor placement should reflect the occupants’ experience of indoor air quality, typically mounted on a wall within the “breathing zone,” 3 to 6 feet above the floor.

It’s often recommended to install air quality monitors in open spaces and rooms that are regularly occupied. Monitors must be placed throughout the project and should be representative of all HVAC zones, building faces, and frequently used areas like lobbies, open and private office areas, and conference rooms.

Looking to spec Kaiterra devices into your project?

Download our sample specification template to make specifying Kaiterra monitors in your next project seamless.

SE mini-pictureA